Please ensure Javascript is enabled for purposes of website accessibility
Inicio > Productos > Anticuerpos > Biosimilares

Anti-Human Axl Reference Antibody (Tilvestamab, RUO) (HB709026)

Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Anti-Human Axl Reference Antibody (Tilvestamab, RUO)
Precio(USD):
Especificación:
  • 100ug
  • 1mg
  • 5mg
  • 10mg
  • 25mg
  • 50mg
  • 100mg
Número:
Contáctenos
  • Vista general

  • Imágenes

  • Referencias

  • Datasheet

  • SDS

Vista general
Número de catálogoHB709026
Descripción
Tilvestamab (HB709026) is a research-grade recombinant antibody targeting UFO. Produced in mammalian cells with native-like glycosylation.
Highlights
  • ●Research Grade — For PK/PD studies, assay development, and ADA research.
  • ●Native Glycosylation — Mammalian expression ensures native-like patterns.
Reactividad de especiesHuman
AplicacionesELISA, Bioactivity: FACS, Functional assay, Research in vivo
Especie huéspedHuman
ClonalidadMonoclonal
IsotipoIgG1-kappa
Sistema de expresión Mammalian cells
Aplicaciones probadas FCM
Objetivo UFO, AXL oncogene, Tyrosine-protein kinase receptor UFO, AXL
Nivel de endotoxinas < 10 EU/mg
Pureza >95% purity as determined by SDS-PAGE.
Purificación Protein A/G purified from cell culture supernatant.
Número de acceso P30530
Forma Liquid
Buffer de almacenamiento 0.01M PBS pH 7.4

Consulte la información específica del buffer en la copia impresa del datasheet o en el COA específico del lote.

Estabilidad y almacenamiento Use a manual defrost freezer and avoid repeated freeze thaw cycles. Store at 2 to 8°C for frequent use. Store at -20 to -80°C for twelve months from the date of receipt.
Nombres alternativosAb-2, BGB-149, 2226775-26-2
Fondo

Tyrosine-protein kinase receptor UFO (AXL) is a ~98 kDa protein. Receptor tyrosine kinase that transduces signals from the extracellular matrix into the cytoplasm by binding growth factor GAS6 and which is thus regulating many physiological processes including cell survival, cell proliferation, migration and differentiation. Ligand binding at the cell surface induces dimerization and autophosphorylation of AXL. Following activation by ligand, AXL binds and induces tyrosine phosphorylation of PI3-kinase subunits PIK3R1, PIK3R2 and PIK3R3; but also GRB2, PLCG1, LCK and PTPN11. Other downstream substrate candidates for AXL are CBL, NCK2, SOCS1 and TNS2. Recruitment of GRB2 and phosphatidylinositol 3 kinase regulatory subunits by AXL leads to the downstream activation of the AKT kinase.

Nota For research use only. Not suitable for clinical or therapeutic use.
Isotype Control Anti-LASV GPC Recombinant Antibody (Fab 37.7) (VK453013)
Imágenes
  • Anti-Human Axl Reference Antibody (Tilvestamab, RUO)

    Bioactivity

    SEC-HPLC detection for Research Grade Tilvestamab.

  • Anti-Human Axl Reference Antibody (Tilvestamab, RUO)

    SDS-PAGE

    SDS-PAGE for Research Grade Tilvestamab.

  • Anti-Human Axl Reference Antibody (Tilvestamab, RUO)

    Flow CytoMetry

    Flow-cytometry using APC anti-human AXL antibody. U251 cells were stained with an irrelevant antibody (Blue Histogram) or an APC anti-human AXL monoclonal antibody (Catalog: HB709026, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

  • Anti-Human Axl Reference Antibody (Tilvestamab, RUO)

    Flow CytoMetry

    Flow-cytometry using PE anti-human AXL antibody. U251 cells were stained with an irrelevant antibody (Blue Histogram) or an PE anti-human AXL monoclonal antibody (Catalog: HB709026, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

  • Anti-Human Axl Reference Antibody (Tilvestamab, RUO)

    Flow CytoMetry

    Flow-cytometry using FITC anti-human AXL antibody. U251 cells were stained with an irrelevant antibody (Blue Histogram) or an FITC anti-human AXL monoclonal antibody (Catalog: HB709026, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

Referencias
Formula
Mass (g) = Concentration (mol/L) × Volume (L) × MW (g/mol)
Enter any 2 of Mass, Concentration, Volume + Molecular Weight to solve for the unknown.
Mass
=
Concentration
×
Volume
Molecular Weight *
g/mol
Formula
C₁ × V₁ = C₂ × V₂
Enter any 3 of the 4 values to solve for the unknown.
Stock Solution
C₁ (Stock Conc.)
×
V₁ (Stock Vol.)
=
Working Solution
C₂ (Working Conc.)
×
V₂ (Working Vol.)
Recomendación

Contáctenos para cotizaciones personalizadas, solicitudes en masa y cualquier otro problema.

Correo: [email protected]

Lista de distribuidores