Please ensure Javascript is enabled for purposes of website accessibility
ホーム > 製品 > 抗体 > フローサイトメトリー抗体

Anti-Human CLDN1/Claudin-1 Recombinant Antibody (6F6C3), FITC (HF976117)

価格(USD):
スペック:
  • 50T
  • 100T
数量:
お問い合わせ
  • 概要

  • イメージ

  • 参考文献

  • データシート

  • SDS

概要
カタログ番号HF976117
種反応性Human
アプリケーションELISA, FCM
宿主種Mouse
クローン性Monoclonal
アイソタイプIgG2a, kappa
クローンID6F6C3
抱合FITC
ターゲット CLDN1, Senescence-associated epithelial membrane protein, CLD1, Claudin-1, SEMP1
エンドトキシンレベル Please contact with the lab for this information.
関連製品 Mouse IgG2a, kappa Recombinant Isotype Control Antibody (MOPC-173), FITC
アクセッション番号 O95832
形態 Liquid
保存バッファー 0.01M PBS, pH 7.4, 0.2% BSA, 0.05% Proclin 300.

データシートのハードコピーまたはロット固有のCOAに記載された具体的なバッファー情報を参照してください。

安定性と保存 Store at 4°C for 12 months. Protect from light. Do not freeze.
背景

Claudin-1 (CLDN1) is a ~22 kDa protein. Claudins function as major constituents of the tight junction complexes that regulate the permeability of epithelia. While some claudin family members play essential roles in the formation of impermeable barriers, others mediate the permeability to ions and small molecules. Often, several claudin family members are coexpressed and interact with each other, and this determines the overall permeability. CLDN1 is required to prevent the paracellular diffusion of small molecules through tight junctions in the epidermis and is required for the normal barrier function of the skin. Required for normal water homeostasis and to prevent excessive water loss through the skin, probably via an indirect effect on the expression levels of other proteins, since CLDN1 itself seems to be dispensable for water barrier formation in keratinocyte tight junctions.

1. Kirschner, N. et al. (2013) The Journal of investigative dermatology 133, 1161-9. PMID: 23407391
注意事項 For flow cytometric staining, the suggested use of this reagent is 0.5 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application. For research use only.
イメージ
参考文献
Formula
Mass (g) = Concentration (mol/L) × Volume (L) × MW (g/mol)
Enter any 2 of Mass, Concentration, Volume + Molecular Weight to solve for the unknown.
Mass
=
Concentration
×
Volume
Molecular Weight *
g/mol
Formula
C₁ × V₁ = C₂ × V₂
Enter any 3 of the 4 values to solve for the unknown.
Stock Solution
C₁ (Stock Conc.)
×
V₁ (Stock Vol.)
=
Working Solution
C₂ (Working Conc.)
×
V₂ (Working Vol.)
レコメンデーション

お問い合わせ カスタムクォート、大量リクエストおよびその他の問題については

メール: [email protected]

ディストリビューターリスト