Please ensure Javascript is enabled for purposes of website accessibility
홈 > 제품 > 항체 > 1차 항체

InVivoMAb Anti-Human PD-L1 Antibody (PRO304397) (HV974010)

InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)
가격(USD):
사양:
  • 100ug
  • 1mg
수량:
문의하기
  • 개요

  • 이미지

  • 참고 문헌

  • 데이터시트

  • SDS

개요
카탈로그 번호HV974010
설명
InVivoMAb Anti-Human/Mouse CD274/PD-L1/B7-H1 Antibody (PRO304397) [PRO304397] (HV974010) is a mouse monoclonal antibody detecting Programmed cell death 1 ligand 1 in FuncS. Suitable for Human.
종 반응성Human
응용 분야FuncS
숙주 종Mouse
클론성Monoclonal
이소타입IgG2a, kappa
클론 IDPRO304397
테스트된 응용 분야 FCM
타겟 B7 homolog 1, B7-H1, B7H1, CD274, PD-L1, PDCD1 ligand 1, PDCD1L1, PDCD1LG1, PDL1, Programmed cell death 1 ligand 1, Programmed death ligand 1
내독소 수준 < 1 EU/mg
순도 >95% as determined by SDS-PAGE.
관련 제품 pH 7.4 Dilution Buffer
정제 Protein A/G purified from cell culture supernatant.
등록번호 Q9NZQ7
형태 Liquid
저장 완충액 0.01M PBS pH 7.4.

데이터시트 인쇄본 또는 로트별 COA에 기재된 구체적인 완충액 정보를 참조하세요.

안정성 및 저장 Use a manual defrost freezer and avoid repeated freeze thaw cycles. Store at 2 to 8°C for frequent use. Store at -20 to -80°C for twelve months from the date of receipt.
배경

Programmed cell death 1 ligand 1 (CD274/PD-L1) is a ~33 kDa protein. Plays a critical role in induction and maintenance of immune tolerance to self. As a ligand for the inhibitory receptor PDCD1/PD-1, modulates the activation threshold of T-cells and limits T-cell effector response. Through a yet unknown activating receptor, may costimulate T-cell subsets that predominantly produce interleukin-10 (IL10). Can also act as a transcription coactivator: in response to hypoxia, translocates into the nucleus via its interaction with phosphorylated STAT3 and promotes transcription of GSDMC, leading to pyroptosis. CD274 is the therapeutic target of atezolizumab (Tecentriq) and durvalumab (Imfinzi).

1. Freeman, GJ. et al. (2000) The Journal of experimental medicine 192, 1027-34. PMID: 11015443
2. Mezzadra, R. et al. (2017) Nature 549, 106-110. PMID: 28813410
3. Burr, ML. et al. (2017) Nature 549, 101-105. PMID: 28813417
4. Huang, X. et al. (2019) Cancer immunology research 7, 1580-1590. PMID: 31399419
5. Kennedy, A. et al. (2023) The EMBO journal 42, e111556. PMID: 36727298
6. Dong, H. et al. (1999) Nature medicine 5, 1365-9. PMID: 10581077
7. Hou, J. et al. (2020) Nature cell biology 22, 1264-1275. PMID: 32929201
참고사항 For research use only. Not suitable for clinical or therapeutic use.
Isotype Control Mouse IgG2a (Fc Silence) Recombinant Isotype Control (MOPC 173) (MF533023)
이미지
  • InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)

    SDS-PAGE

    SDS-PAGE for InVivoMAb Anti-Human/Mouse CD274/PD-L1/B7-H1 Antibody (PRO304397).

  • InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)

    Flow CytoMetry

    Flow-cytometry using APC anti-human CD274 antibody. MDA-MB-231 cells were stained with an irrelevant antibody (Blue Histogram) or an APC anti-human CD274 monoclonal antibody (Catalog: HV974010, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

  • InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)

    Flow CytoMetry

    Flow-cytometry using FITC anti-human CD274 antibody. MDA-MB-231 cells were stained with an irrelevant antibody (Blue Histogram) or an FITC anti-human CD274 monoclonal antibody (Catalog: HV974010, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

  • InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)

    Flow CytoMetry

    Flow-cytometry using PE anti-human CD274 antibody. MDA-MB-231 cells were stained with an irrelevant antibody (Blue Histogram) or an PE anti-human CD274 monoclonal antibody (Catalog: HV974010, Yellow Histogram) at a concentration of 5 µg/ml for 30 mins at RT. After washing, cells analysed on a NovoCyte Flow Cytometer.

  • InVivoMAb Anti-Human PD-L1 Antibody (PRO304397)

    Flow CytoMetry

    Flow-cytometry using anti-human CD274 antibody. Untransfected cells (blue Histogram) and Transfected cells (Yellow Histogram) were stained with an anti-human CD274 monoclonal antibody (Catalog: HV974010) at a concentration of 5 µg/ml for 30 mins at RT. After washing, bound antibody was detected using a Goat Anti-Mouse IgG H&L Polyclonal Antibody, FITC (abinScience: MF690414) and cells analysed on a NovoCyte Flow Cytometer.

참고 문헌
Formula
Mass (g) = Concentration (mol/L) × Volume (L) × MW (g/mol)
Enter any 2 of Mass, Concentration, Volume + Molecular Weight to solve for the unknown.
Mass
=
Concentration
×
Volume
Molecular Weight *
g/mol
Formula
C₁ × V₁ = C₂ × V₂
Enter any 3 of the 4 values to solve for the unknown.
Stock Solution
C₁ (Stock Conc.)
×
V₁ (Stock Vol.)
=
Working Solution
C₂ (Working Conc.)
×
V₂ (Working Vol.)
추천

문의하기 맞춤형 견적, 대량 주문 및 기타 문의 사항은

메일: [email protected]

배급사 목록